Your Blue Star AC shows a code like E1, F2, H6 or P8 when its PCB detects a fault — this guide lists every common Blue Star AC error code by model series, what the problem is, and how to fix it, in plain language for both home users and repair technicians.

How to Read a Blue Star AC Error Code

The same code can mean different faults on different Blue Star series, so always match the code with your model series first. For example, E1 is a room sensor fault on a window AC but an EEPROM (memory) error on RA/RB/TA/TB split ACs.

  1. Read the code. Most split and inverter models show it on the indoor unit display (E1, F2, H6, P8). Some older models flash an LED a set number of times instead — count the blinks.
  2. Find your model number. It is printed on the sticker on the side of the indoor unit and on the bill. The series letters inside it (for example RA, TA, FA, VA, ZA, JA, NA, or C-Series/S-Series inverter) tell you which table below to use.
  3. Note when it appears. At power-on, after a few minutes of running, or only in hot weather — this helps find the cause fast.
  4. Reset once. Switch off from the main switch/MCB, wait 5 minutes, switch on. If the code comes back, the fault is real.

Safety first: an inverter AC PCB holds high DC voltage (around 300 V+) in its capacitors even after you unplug it. Non-technical users should only do the easy checks in this guide. Opening the PCB is for trained technicians. If your AC is under warranty, book an authorised Blue Star service visit before opening anything.Troubleshooting flowchart: what to do when a Blue Star AC shows an error code.

Blue Star Inverter AC Error Codes: Quick List

This list matches the codes published for current Blue Star inverter split ACs such as BO-IA518DLU, BO-IC312YATU, BO-IC318YBTU, BO-IC324YATU and BO-5CNHW12QATU / BO-5CNHW18QATU. Older and non-inverter series use different codes — if your series is listed in the next section, use that table instead.

CodeMain problemSolution
E0Indoor unit (IDU) EEPROM faultReset power; if it stays, reprogram or replace the indoor PCB
E1Outdoor coil temperature too highClean condenser coil, check outdoor fan runs, check for refrigerant overcharge
E2Indoor coil frozen protectionClean filters and indoor coil, check indoor fan speed and gas level
E4Outdoor discharge temperature too highUsually low gas / leak or restricted flow; clean filter, check gas and leak
E5Over-current protection (AC input on most models; compressor over-current on BO-IA518DLU)Check supply voltage, wiring and compressor current
E6Indoor–outdoor communication errorCheck signal wire continuity, loose terminals and cable earthing
E8Zero-crossing errorSwitch off 5–10 minutes and restart; if it repeats, repair indoor PCB zero-cross circuit
EEOutdoor unit (ODU) EEPROM faultReprogram or replace the outdoor PCB
ECRefrigerant leak detectedFind and repair leak, vacuum, recharge by weight
EUIPM over-temperature, frequency reducedCheck IPM heatsink contact and outdoor airflow
F1Indoor room temperature sensor faultCheck connector; replace sensor
F2Indoor coil temperature sensor faultCheck wiring and connector; replace sensor
F3Outdoor ambient temperature sensor faultCheck connector; replace sensor
F4Outdoor coil temperature sensor faultReplace sensor
F5Outdoor discharge temperature sensor faultReplace sensor
H6Indoor fan motor faultCheck motor wires (rodent damage), motor, then indoor PCB
L1 / L2Input voltage too high / too lowCheck mains voltage; install a stabiliser
L3Outdoor BLDC fan motor faultCheck fan blade, motor plug, motor and fan drive
L4Phase current sampling abnormalOutdoor PCB current-sense fault; repair or replace board
LCCompressor start failure / out of stepCheck compressor windings, IPM and voltage
P3Compressor overload / drive phase over-currentCheck gas pressure, condenser airflow, compressor
P4DC bus voltage high or lowCheck input voltage, rectifier, DC bus capacitors
P5Compressor phase over-currentCheck compressor wiring and current before resetting
P7IPM errorTest IPM; replace module or outdoor board
P8IPM over-temperatureCheck heatsink screws and paste, outdoor fan, gas
PHAC over-voltage / under-voltageInstall stabiliser; check house wiring and earth
CodeMain problemSolution
DHDC bus over-voltageCheck mains voltage and DC bus capacitors
DLDC bus under-voltageCheck mains voltage, rectifier, capacitors
HECompressor over-current (hardware detection)Check compressor windings and IPM
HPPFC over-current (hardware)Check PFC circuit and reactor wiring
PCPFC over-current (firmware)Check PFC circuit and supply
IPPhase leakageCheck compressor insulation to body and wiring
LOCompressor step-outCheck U/V/W wiring, compressor, IPM

Extra Codes on BO-IA518DLU

This model uses these additional codes (the rest match the table above).

One website lists E1 as a communication error on the BO-IC3xxY models. If E1 appears and the outdoor unit never starts, check the communication wire as well.

Blue Star AC Error Codes by Model Series

Match the series letters in your model number with the headings below. Series names are as listed by published service guides; if your model isn’t listed, use the quick list above and confirm with your user manual.

Window AC – L Series and G Series

CodeMain problemSolution
E1Room temperature sensor failureReconnect sensor wire; replace sensor; check PCB if sensor is fine
E2Evaporator coil sensor failureReconnect or replace the coil sensor

Window AC – Y, R and M Series

CodeMain problemSolution
ErIndoor ambient sensor failureHeat can melt the sensor terminal; reconnect or replace sensor
EnEvaporator pipe sensor failureFix root cause (gas or PCB), then reconnect or replace sensor
EoCondenser pipe sensor failureCheck gas, inspect PCB, replace sensor if damaged
EdEvaporator defrostingDirty filter, dirty coil or low fan speed; clean filters and coil, check fan

Split AC – 2-star RA/RB, 3-star TA/TB, 5-star DA/DB, 3-star FA/FB/FC

CodeMain problemSolution
E1EEPROM errorIndoor PCB memory fault; authorised technician replaces/reprograms board
E2Zero-crossing errorRepair zero-cross circuit on indoor PCB
E3Indoor fan speed out of controlReplace fan capacitor; check PG motor and its feedback
E4Compressor over-current (4 times)Check wiring and input current; don’t keep resetting, it can damage the compressor
E5Room temperature sensor open/shortReconnect or replace sensor
E6Evaporator sensor open/shortReconnect or replace sensor
E7Condenser coil sensor open/short (FA/FB/FC only)Reconnect or replace sensor
ECRefrigerant leak (FA/FB/FC only)Find leak, repair/replace pipe, recharge gas
E9Indoor–outdoor communication errorCheck and replace broken connecting wire

Split AC – 3-star VA/VB/VC/VD, 2-star OA/OB/OC, 5-star ZA/ZB/ZC/ZD, 5-star SA/SB, SAF/ZAF, 3HS18TAT

CodeMain problemSolution
F1Indoor ambient sensor open/shortCheck connector; reconnect or replace sensor
F2Indoor evaporator sensor open/shortCheck connector; reconnect or replace sensor
H6Indoor fan (PG motor) not runningCheck PCB connector and solder joints; replace capacitor or motor
C5Jumper cap faultJumper cap missing or in wrong pins; reseat or replace
U8PG motor zero-cross circuit faultRepair zero-cross circuit on indoor PCB
E5Over-current protectionCheck fuse and MCB; check supply voltage if it repeats
FALow frequency due to high pipe temperatureUsually gas problem; check gas pressure
FHLow frequency, anti-freezeIndoor fan problem; check motor and capacitor

Split AC – Old Star-Rated, Non-Star, DC Inverter C-Series and S-Series

CodeMain problemSolution
E0Low running frequency due to low voltageCheck input voltage; use a stabiliser
E1High-pressure protectionClean condenser; check pressure switch
E2Indoor anti-freeze protectionRestart; clean filter/coil; technician if it repeats
E3Low-pressure protectionCheck gas level and low-pressure switch
E4Compressor discharge problemAir in system or blocked condenser; technician vacuums and recharges
E5Low voltage / over-current (overload on S-Series)Reset MCB; use a stabiliser
E6Communication failureCheck connecting wires; replace damaged cable
E7Mode conflictCheck indoor/outdoor unit compatibility
E8Anti-high-temperature protectionLow refrigerant flow; check gas
E9Anti-cold-wind protectionCheck pressure; check gas charge
F1 / F2Indoor ambient / evaporator sensor open or shortReconnect or replace sensor
F3 / F4Outdoor ambient / condenser sensor open or shortReconnect or replace sensor
F5Discharge sensor open or shortCheck wiring and fuse; replace sensor
F6Low frequency, cooling overloadBlower motor issue; replace capacitor or repair motor
F7Oil return in cooling modeCheck oil return valve
F8Low frequency, over-currentCheck supply and wiring
F9Low frequency, high dischargeClean condenser; check gas and airflow
H1DefrostNormal in heating mode; wait and restart
H2Static dust removal protectionClean the filters
H3Compressor overload protectionCheck compressor and its overload; find cause before resetting
H4System abnormalFull check of fan speed, gas and compressor
H5IPM module protectionCheck IPM, compressor current and supply
H6No feedback from indoor fan motorCheck motor plug, wiring and PCB fan circuit
H7Synchronisation failureCheck indoor/outdoor PCB compatibility and wiring
H8Water-full (portable AC)Empty the water tank
H9Electric heater faultRepair or replace heater
C5Jumper cap faultReseat or replace jumper
U1Compressor phase current detection faultCheck current-sense circuit on outdoor PCB
U3DC bus voltage dropCheck input voltage; use stabiliser
U5Unit current detection faultCheck installation and outdoor PCB
U74-way valve abnormalCheck valve coil; replace valve
U8PG motor zero-cross faultRepair indoor PCB zero-cross circuit
U9Outdoor zero-cross faultRepair outdoor PCB zero-cross circuit
P5Compressor phase over-currentCheck current and wiring before resetting
P7IPM temperature sensor / IPM errorReconnect sensor; check IPM and gas flow
P8IPM high temperatureCheck heatsink, outdoor fan and gas
PHDC bus voltage too high (S-Series)Over-voltage; use stabiliser
PLDC bus voltage too lowFix voltage fluctuation
PUCapacitor charging faultCheck DC bus capacitor and charging circuit
HCPFC protectionCheck PFC circuit, wiring and MCB
LCCompressor start failureCheck all circuits, compressor and IPM
L3Outdoor fan module protection (S-Series)Check and repair outdoor fan motor
EEEEPROM errorPCB memory fault; technician needed
EUFrequency limited, IPM high temperatureCheck IPM heatsink contact and outdoor airflow
FHFrequency limited, anti-freezeCheck indoor fan motor and capacitor

Split AC – 3-star JA, JB, J3

CodeMain problemSolution
F1Room temperature sensor errorReconnect or replace sensor
F2Pipe temperature sensor errorReconnect or replace sensor
F4PG motor errorCheck indoor fan motor and feedback

Split AC – 2-star NA, NB, NM3 and 3-star HAF

CodeMain problemSolution
E1Air intake temperature sensor abnormalReconnect or replace sensor
E2Outdoor coil sensor abnormalReconnect or replace sensor
E3Indoor coil sensor abnormalReplace sensor
E4Indoor PG motor feedback abnormalRepair or replace fan motor

Blue Star AC PCB Repair Guide (For Technicians)

Most Blue Star PCB faults come from voltage surges, loose connectors, moisture, or lizards and insects inside the board area. Check the cheap parts first before replacing the full PCB.

Inverter AC outdoor PCB sections and error codes repair map

Which section of the inverter outdoor PCB to check for each error code.

Before you start: switch off the MCB, wait at least 5 minutes, and discharge the DC bus capacitors on inverter outdoor boards. Take a photo of every connector before removing it.

  1. Look at the board. Check for burnt marks, bulged capacitors, cracked solder joints near relays and connectors, corrosion, and insect or lizard remains. Clean with IPA and a soft brush.
  2. Check the input fuse and varistor (MOV). A blown fuse with a burnt MOV usually means a high-voltage surge. Replace both, then find why the surge happened (no stabiliser, loose neutral).
  3. Check the power supply (SMPS) outputs. Measure the low-voltage rails on the indoor PCB (usually 12 V and 5 V DC). No 5 V = display dead, no beep, no remote response.
  4. Test the sensors (F1–F5, E5/E6, Er/En codes). Unplug and measure resistance. On models like BO-IA518DLU, the room, indoor coil, outdoor ambient, outdoor coil and discharge sensors are all 10 kΩ types. Some outdoor boards use a higher-value sensor (about 45 kΩ), so check the value marked on the sensor or in the service manual. Open (infinite) or shorted (near 0 Ω) = replace the sensor. If the sensor is fine, check the connector and the PCB sensor circuit.
  5. Indoor fan / PG motor (H6, E3, F4, U8 codes). Check the fan capacitor, the motor plug, and the hall-sensor feedback wire. If the motor turns by hand and the capacitor is good, test the fan triac/driver on the PCB and the zero-cross circuit.
  6. Communication error (E6, E9). Check the indoor–outdoor cable for cuts and loose terminals, and that L, N and signal wires are not swapped. Measure the signal line voltage while running; no change = faulty communication circuit (optocoupler) on one of the boards.
  7. Outdoor inverter board (P, L, H5, LC, PH, PU codes). Test the bridge rectifier, DC bus capacitors, PFC section and the IPM module (diode test between P/N and U/V/W). Check the IPM heatsink screws and thermal paste. Test compressor windings: U-V, V-W and W-U should read equal low ohms and none should touch the body.
  8. EEPROM errors (E0, EE, E1 on RA/TA/FA series). Reseat the board and reset power. If it stays, the EEPROM needs reprogramming with the correct data or the board must be replaced with the same part number.
  9. Replace with the right part. Use the same PCB part number printed on the board. A wrong board can show communication or mode-conflict errors.

When to replace instead of repair: a burnt IPM with track damage, repeated EEPROM errors, or a board that failed after a heavy surge is usually cheaper and safer to replace. Always install a stabiliser after a surge-related repair.

Step-by-Step Blue Star AC Repair by Error Code

Use these procedures after matching your code in the tables above. The values given are typical for inverter split ACs; the service manual for your exact model is the final reference.

Tools needed: digital multimeter (with diode test and capacitance), clamp meter, insulation tester (megger) if available, manifold gauge set for R32/R410A, vacuum pump with micron gauge, insulated screwdrivers, soldering iron, IPA cleaner, and a resistor or bulb for discharging capacitors.

1. Sensor Errors (F1, F2, F3, F4, F5, b5; E5/E6 on RA/TA series; Er/En/Eo on window ACs)

How to test Blue Star AC temperature sensor with multimeter for F1 F2 F3 F4 F5 errors
  1. Switch off the MCB and wait 5 minutes.
  2. Find the sensor plug on the PCB. On BO-IA518DLU: indoor room sensor = red plug, indoor coil = white; outdoor ambient = white, outdoor coil = blue, discharge = red.
  3. Unplug it and check the pins for rust, burning or loose crimping.
  4. Measure resistance across the sensor. A 10 kΩ sensor reads about 10 kΩ at 25 °C, more when cold, less when warm. OL (open) or near 0 Ω (short) = replace.
  5. Hold the sensor tip in your hand. The reading should fall slowly and smoothly; jumping values mean a bad sensor.
  6. If the sensor is good, power the board and measure DC voltage at the empty sensor socket. About 5 V means the PCB side is fine; 0 V points to a fault in the board’s sensor circuit or a broken track.
  7. Fit a sensor of the same value, put it back in the same pocket or clip on the pipe, and reset the AC.

2. Communication Error (E6; E9 on RA/TA series)

Blue Star AC E6 communication error indoor outdoor wiring check
  1. Check that the terminal numbers match at the indoor and outdoor terminal blocks (L, N, signal, earth). Swapped wires are common after shifting an AC.
  2. Look for joints, cuts or rodent damage on the interconnecting cable. Check each core end-to-end for continuity and make sure no core touches another.
  3. Check the earth wire and the shielded cable grounding.
  4. Power on and measure AC voltage between L and N at the outdoor terminal (about 230 V). No voltage = indoor relay or wiring fault.
  5. Measure the signal wire against N with the AC running. It should show a changing DC voltage. A steady reading means one board is not sending data.
  6. Check the outdoor board is alive: fuse, LED, rectifier and SMPS. A dead outdoor board gives E6 too.
  7. Change a board only after the wiring is confirmed good. After replacing a board, confirm the part number matches the model, or you may get mode-conflict or sync errors (E7, H7).

3. Indoor Fan Motor Errors (H6; E3 on RA/TA; F4 on JA/JB; E4 on NA/NB; U8)

AC fan motor connector pinout PG motor and BLDC motor for H6 error
  1. With power off, turn the blower by hand. If it is tight or rubbing, clean the blower wheel and check the bearing.
  2. Check the motor wires for rodent damage and the plug on the PCB.
  3. AC (PG) motor: test the fan capacitor against its rated µF and measure the motor windings. The PG feedback plug has 3 wires (5 V, ground, signal); turning the blower by hand should make the signal pulse between 0 and 5 V.
  4. BLDC motor (newer inverter models): the plug usually carries about 310 V DC, 15 V DC, a speed signal (Vsp) and a feedback signal (FG). If 310 V, 15 V and Vsp are all present and the motor does not run, replace the motor.
  5. If the supply or speed signal is missing, the indoor PCB is faulty (fan triac, driver or zero-cross circuit). Replace the motor first only if the motor tests bad, then the PCB.

4. Power Module and Voltage Errors (P7, P8, EU, PH, P4, L1, L2, DH, DL, PU, HC, HP, PC)

Inverter AC IPM module diode test for P7 P8 EU errors
  1. Switch off and discharge the DC bus capacitors through a resistor or bulb. Confirm below 10 V with the meter before touching anything.
  2. Measure the mains voltage at the outdoor unit while it runs. Large swings or very high or low voltage are the most common cause — fit a proper stabiliser and fix loose neutral or earth.
  3. For P8 and EU (heat): check the outdoor fan runs, the condenser is clean, the IPM heatsink screws are tight, and the thermal paste is not dry. Re-apply paste if needed.
  4. Test the IPM on diode mode with the compressor wires removed: red probe on U, V or W and black on P should read about 0.3–0.6 V; red on N and black on U, V or W should read the same. Reversed probes should read OL. 0 V on any pair = shorted IPM.
  5. Check the bridge rectifier, and the DC bus capacitors for bulging or low capacitance. With power on, the DC bus is normally about 310–340 V.
  6. For PFC codes (HC, HP, PC), check the PFC reactor wiring and the PFC switching device and diode.
  7. If P7 stays even though the IPM tests fine, the fault is in the IPM driver or its temperature sensing. Replace the outdoor board with the same part number.

5. Compressor Errors (LC, LO, P5, P3, HE, H3; E4 on RA/TA series)

Inverter compressor U V W winding and insulation test for LC P5 errors
  1. Do not keep resetting these codes. Repeated restarts can burn the compressor or IPM.
  2. Remove the U, V, W wires. Measure U–V, V–W and W–U. All three should be equal and low (a few ohms). Unequal or open = compressor winding fault.
  3. Check each terminal to the compressor body. The multimeter should read OL; a megger should read above 2 MΩ. A low reading = grounded compressor (also causes the IP code).
  4. Check the U, V, W order and crimps against the wiring diagram. A wrong order or loose terminal causes step-out (LC, LO).
  5. Check gas pressures. Overcharge or a blocked condenser raises compressor current.
  6. If windings, insulation and IPM are all good but the compressor still won’t start and draws very high current, the compressor is mechanically stuck.

6. Gas and Temperature Errors (EC, E1, E4, E2, FA, E8 on C/S series)

  1. Clean the filters, indoor coil and outdoor coil, and confirm both fans run.
  2. Connect the gauge to the service port and compare the running pressure with the chart for your refrigerant in the service manual.
  3. Low pressure, poor cooling, plus EC or E4 = gas leak. Test flare joints with soap water first (the most common leak point), then the indoor coil and outdoor coil.
  4. High pressure with a hot outdoor coil plus E1 = dirty condenser, outdoor fan fault, or overcharge.
  5. Repair the leak, pressure-test with dry nitrogen, vacuum to below 500 microns, and charge by weight as per the nameplate.
  6. R32 gas is mildly flammable. Never braze with gas in the system, and keep the area ventilated.

7. EEPROM Errors (E0, EE; E1 on RA/TA/DA/FA series)

  1. Switch off the MCB for 5 minutes and restart.
  2. Check the board for moisture, corrosion or insect damage near the 8-pin EEPROM chip and clean it with IPA.
  3. If the code stays, the EEPROM data is corrupt. Reprogram it only if you have the correct data for that exact model; otherwise replace the board with the same part number.

8. Outdoor Fan Error (L3)

  1. Check the fan blade turns freely and is not cracked or touching the grille.
  2. Check the motor plug on the outdoor PCB.
  3. Like the indoor BLDC motor, check for supply voltages and the speed signal. Supply present but no rotation = motor; supply missing = outdoor PCB.

After Any Repair

Run the AC for at least 30 minutes in cooling mode. Check the running current with a clamp meter against the nameplate, confirm normal gas pressure and good cooling, and make sure no error code returns.

Easy Checks Anyone Can Do Before Calling a Technician

These safe steps fix many Blue Star error codes without opening the AC.

  • Reset the AC: switch off the MCB for 5 minutes, then switch on.
  • Clean the air filters: a dirty filter causes freezing (E2, Ed, FH) and high-temperature codes.
  • Check the voltage: low or high voltage causes E0, E5, PH, PL and U3. Use a good stabiliser if your area has fluctuations.
  • Clear the outdoor unit: remove boxes, leaves and plants; keep about 60 cm open space so hot air can escape (helps E1, E4, E8, P8).
  • Wash the outdoor coil gently with low-pressure water if it is dusty (power off first).
  • Check remote batteries and mode: a wrong mode or weak batteries can look like a fault.
  • Empty the water tank on portable ACs (H8).

If the code returns after these checks, note the code, your model number and when the error appears, and call Blue Star customer care (1800 209 1177, toll-free) or a trained technician. Do not keep resetting compressor or over-current codes (E4, E5, H3, P5) — repeated restarts can damage the compressor.

Blue Star AC Error Code FAQ

What is E1 error in Blue Star AC? It depends on the model. On window ACs (L/G series) E1 is a room sensor failure; on RA/RB/TA/TB/DA/DB/FA split ACs it is an EEPROM error; on older and C/S-Series ACs it is high-pressure protection; on newer inverter models such as BO-IA518DLU and BO-5CNHW12QATU it means the outdoor coil temperature is too high.

What does E6 mean in Blue Star inverter AC? On most inverter models E6 is a communication error between the indoor and outdoor units. Check the connecting cable and terminals first.

What is H6 error in Blue Star AC? H6 means the indoor fan motor is not running or not giving feedback to the PCB. Check the fan capacitor, motor plug and the PCB fan circuit.

What is F1 and F2 error in Blue Star AC? F1 is an indoor room temperature sensor fault and F2 is an indoor coil (evaporator) sensor fault. Reconnecting or replacing the sensor usually fixes them.

What is P8 error in Blue Star AC? P8 is IPM (power module) overheating protection on the outdoor inverter board. Check the outdoor fan, heatsink and gas level.

Can I reset a Blue Star AC error code myself? Yes. Switch off the main MCB for 5 minutes and switch on again. If the code comes back, the fault needs repair.

Is Blue Star AC PCB repair costly? Sensor, fuse and capacitor repairs are cheap. A full inverter outdoor PCB replacement costs much more, so a technician should test the board before replacing it.

SEO Pack (for publishing)

FieldUse this
SEO title (under 60 characters)Blue Star AC Error Codes List & PCB Repair Guide 2026
Meta description (under 160 characters)All Blue Star AC error codes (E1, E6, F1, H6, P8 & more) by model series, with main problem and easy fix. PCB repair guide for technicians.
URL slug/blue-star-ac-error-codes-pcb-repair
Focus keywordBlue Star AC error codes
Secondary keywordsBlue Star inverter AC error code, Blue Star AC PCB repair, Blue Star AC E1 error, Blue Star AC E6 error, Blue Star AC H6 error, Blue Star split AC error code list, Blue Star AC problem and solution, Blue Star AC PCB repair step by step, Blue Star AC sensor value
Image alt textBlue Star AC indoor unit showing error code on display
SchemaAdd FAQPage schema using the FAQ section above

Tips: keep the H1 as the title above, add a table of contents at the top, link to your related AC repair posts, and update the “as of” date when you add new codes.